Follow the following steps to solve the above issue and its solution
Alarm : Control Service
Sum: The Log SMS Command has reached the configurable limit.You sholud perform a backup
and clean the table.
Event ID: 11045
Steps1:
Open PISYS Configuration builder,
|System
|Control System
|Server Setup
| System Checks
|Log SMS Command , in this option change the
"Table exceed Limit: 3,00,000. Here we changed this value to 10,00,000." Then "SAVE" and "CLOSE".
After the first step,close all PISYS applications which were opened and follow the step2.
Step2:
a.Right on the Mycomputer Icon,
|Manage
|Services and Applications
|Services
|PISYS Control Service,right click and select "Restart".
This will stops the PISYS Control Centre.
b. In Computer Management Window,
| Select IIS Manager,right click
|All tasks,select "Restart IIS".,click "O.K".
Now open the PISYS Control Centre ans start the PISYS.